fcγri (cd64) human Search Results


92
Miltenyi Biotec anti human cd64
A schematic diagram on how to calculate the FCBI-index value of the patient with microbiologically confirmed Streptococcus pneumoniae pneumonia using the novel FCBI-index method. (a) The incubation of the whole blood sample with the receptor-specific antibodies, red blood cell lysis, and flow cytometry run were carried out one after another in the same test tube. (b) During the flow cytometry run, the leukocyte population within gate R1 was first gated out from the side scatter (SSC)/MHCI bivariate histogram, after which gates R2 (red) and R3 (blue) were set around neutrophil and lymphocyte populations, respectively, in the <t>SSC/CD64</t> bivariate histogram containing leukocytes inside gate R1. The stop count of 1000 monocytes inside the monocyte gate (black/R4) was used, leading to the collection of a total of 5000–20000 leukocytes. (c) For the purpose of data analysis, three additional bivariate histograms, namely SSC/CD35, SSC/CD64, and SSC/CD329 were made, showing mean fluorescence intensities (MFI, which correlate with the number of receptors on the cell surface) of gated neutrophil (red) and lymphocyte (blue) populations. In the SSC/CD35 histogram, B-lymphocytes expressing CD35 were left outside the lymphocyte gate. (d) The actual FCBI-index value was calculated by substituting the obtained receptor-specific MFI data from neutrophil and monocyte populations into the bacterial infection algorithm. A more detailed step-by-step description of the development of the FCBI-index method is presented in the method section and Supplementary Figs. 1–5. 1.54 × gCMF-HBSS: 1.54-fold calcium- and magnesium-free HBSS -buffer supplemented with 1.54 mg/mL gelatin.
Anti Human Cd64, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/pmc08633870-92-18-25?v=Miltenyi+Biotec
Average 92 stars, based on 1 article reviews
anti human cd64 - by Bioz Stars, 2026-08
92/100 stars
  Buy from Supplier

93
Miltenyi Biotec cd64
Immunophenotyping panel for multiplexed tissue imaging of cancer.
Cd64, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/pmc10985204-62-0-10?v=Miltenyi+Biotec
Average 93 stars, based on 1 article reviews
cd64 - by Bioz Stars, 2026-08
93/100 stars
  Buy from Supplier

90
Promega fcγri (cd64) human
Immunophenotyping panel for multiplexed tissue imaging of cancer.
Fcγri (Cd64) Human, supplied by Promega, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/pm39306747-152-36-39?v=Promega
Average 90 stars, based on 1 article reviews
fcγri (cd64) human - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

94
Bio-Techne corporation recombinant human fc gamma ri/cd64 protein, cf
Immunophenotyping panel for multiplexed tissue imaging of cancer.
Recombinant Human Fc Gamma Ri/Cd64 Protein, Cf, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/custom%401257-fc%4037647390?v=Bio-Techne+corporation
Average 94 stars, based on 1 article reviews
recombinant human fc gamma ri/cd64 protein, cf - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

89
Sino Biological human cd64 / fcgr1a protein
Immunophenotyping panel for multiplexed tissue imaging of cancer.
Human Cd64 / Fcgr1a Protein, supplied by Sino Biological, used in various techniques. Bioz Stars score: 89/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/custom%4010256-h27h%4010481891?v=Sino+Biological
Average 89 stars, based on 1 article reviews
human cd64 / fcgr1a protein - by Bioz Stars, 2026-08
89/100 stars
  Buy from Supplier

91
Bio-Techne corporation human fc gamma ri/cd64 antibody
Immunophenotyping panel for multiplexed tissue imaging of cancer.
Human Fc Gamma Ri/Cd64 Antibody, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fc%CE%B3ri+%28cd64%29+human/bio-techne+corporation___mab1257?v=Bio-Techne+corporation
Average 91 stars, based on 1 article reviews
human fc gamma ri/cd64 antibody - by Bioz Stars, 2026-08
91/100 stars
  Buy from Supplier

Image Search Results


A schematic diagram on how to calculate the FCBI-index value of the patient with microbiologically confirmed Streptococcus pneumoniae pneumonia using the novel FCBI-index method. (a) The incubation of the whole blood sample with the receptor-specific antibodies, red blood cell lysis, and flow cytometry run were carried out one after another in the same test tube. (b) During the flow cytometry run, the leukocyte population within gate R1 was first gated out from the side scatter (SSC)/MHCI bivariate histogram, after which gates R2 (red) and R3 (blue) were set around neutrophil and lymphocyte populations, respectively, in the SSC/CD64 bivariate histogram containing leukocytes inside gate R1. The stop count of 1000 monocytes inside the monocyte gate (black/R4) was used, leading to the collection of a total of 5000–20000 leukocytes. (c) For the purpose of data analysis, three additional bivariate histograms, namely SSC/CD35, SSC/CD64, and SSC/CD329 were made, showing mean fluorescence intensities (MFI, which correlate with the number of receptors on the cell surface) of gated neutrophil (red) and lymphocyte (blue) populations. In the SSC/CD35 histogram, B-lymphocytes expressing CD35 were left outside the lymphocyte gate. (d) The actual FCBI-index value was calculated by substituting the obtained receptor-specific MFI data from neutrophil and monocyte populations into the bacterial infection algorithm. A more detailed step-by-step description of the development of the FCBI-index method is presented in the method section and Supplementary Figs. 1–5. 1.54 × gCMF-HBSS: 1.54-fold calcium- and magnesium-free HBSS -buffer supplemented with 1.54 mg/mL gelatin.

Journal: EBioMedicine

Article Title: Rapid detection of bacterial infection using a novel single-tube, four-colour flow cytometric method: Comparison with PCT and CRP

doi: 10.1016/j.ebiom.2021.103724

Figure Lengend Snippet: A schematic diagram on how to calculate the FCBI-index value of the patient with microbiologically confirmed Streptococcus pneumoniae pneumonia using the novel FCBI-index method. (a) The incubation of the whole blood sample with the receptor-specific antibodies, red blood cell lysis, and flow cytometry run were carried out one after another in the same test tube. (b) During the flow cytometry run, the leukocyte population within gate R1 was first gated out from the side scatter (SSC)/MHCI bivariate histogram, after which gates R2 (red) and R3 (blue) were set around neutrophil and lymphocyte populations, respectively, in the SSC/CD64 bivariate histogram containing leukocytes inside gate R1. The stop count of 1000 monocytes inside the monocyte gate (black/R4) was used, leading to the collection of a total of 5000–20000 leukocytes. (c) For the purpose of data analysis, three additional bivariate histograms, namely SSC/CD35, SSC/CD64, and SSC/CD329 were made, showing mean fluorescence intensities (MFI, which correlate with the number of receptors on the cell surface) of gated neutrophil (red) and lymphocyte (blue) populations. In the SSC/CD35 histogram, B-lymphocytes expressing CD35 were left outside the lymphocyte gate. (d) The actual FCBI-index value was calculated by substituting the obtained receptor-specific MFI data from neutrophil and monocyte populations into the bacterial infection algorithm. A more detailed step-by-step description of the development of the FCBI-index method is presented in the method section and Supplementary Figs. 1–5. 1.54 × gCMF-HBSS: 1.54-fold calcium- and magnesium-free HBSS -buffer supplemented with 1.54 mg/mL gelatin.

Article Snippet: Fluorescence-conjugated receptor-specific monoclonal antibodies (test kit): Phycoerythrin (PE)-conjugated anti-human CD35 (Clone E11) was purchased from Ancell (ANC-184-050), PerCP-Vio700-conjugated anti-human CD64 (Clone 10.1.1) was purchased from Miltenyi Biotec (130-101-422), fluorescein isothiocyanate (FITC)-conjugated anti-human CD329 (Clone 191240) was purchased from R&D systems (FAB1139F) and AF647-conjugated anti-human MHC class I molecule (Clone W6/32) was purchased from R&D systems (FAB7098R). (Supplementary Table 5).

Techniques: Incubation, Red Blood Cell Lysis, Flow Cytometry, Fluorescence, Expressing, Infection

Immunophenotyping panel for multiplexed tissue imaging of cancer.

Journal: Frontiers in Immunology

Article Title: Unveiling spatial complexity in solid tumor immune microenvironments through multiplexed imaging

doi: 10.3389/fimmu.2024.1383932

Figure Lengend Snippet: Immunophenotyping panel for multiplexed tissue imaging of cancer.

Article Snippet: CD64 , REA987 , 50 , 130-116-195 , FITC , Miltenyi Biotec.

Techniques: Imaging